Description
Specification
Insulation resistance
Test voltage 250V 500V 1000V 2500V 5000V
Measuring range 0.0 – 100.0MΩ 0.0 – 99.9MΩ
80 – 1000MΩ 0.0 – 99.9MΩ
80 – 999MΩ
0.80 – 2.00GΩ 0.0 – 99.9MΩ
80 – 999MΩ
0.80 – 9.99GΩ
8.0 – 100.0GΩ 0.0 – 99.9MΩ
80 – 999MΩ
0.80 – 9.99GΩ
8.0 – 99.9GΩ
80 – 1000GΩ
Accuracy ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt
±20%rdg
(100GΩ or more)
Short circuit current 1.5mA
Rated test current 0.7 – 0.9mA at 0.25MΩ load 0.8 – 1mA at 0.5MΩ load 1 – 1.2mA at 1MΩ load 1 – 1.2mA at 2.5MΩ load 1mA – 1.2mA at 5MΩ load
Open circuit current 250V
+10%,-10% 500V
+20%,-10% 1000V
+20%,-0% 2500V
+20%,-0% 5000V
+20%,-0%
Voltage measurement
Measuring range AC: 30 – 600V (50/60Hz)
DC: ±30 – ±600V
Accuracy ±2%rdg±3dgt
General
Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2
IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimension 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Carring case [Hard])
Weight 1.9kg approx. (including batteries)
4kg approx. (including accessories)